<div class="tab-content clearfix ui-tabs-panel ui-widget-content ui-corner-bottom tab-pane active" id="features-tab" role="tabpanel"> <div class="col-sm-12 col-lg-12"> <p> <img alt="" src="http://www.bimel.com.tr/resim/?s=30202" style="width: 450px; height: 362px; float: left; margin: 20px;" /></p> <ul> <li> A humidity and temperature measuring solution for ATEN PG<a href="https://www.aten.com/global/en/resources/feature-articles/3-reasons-why-you-need-pdus-in-your-data-center-now/?utm_medium=internal_link" target="_blank"> PDU</a> series</li> <li> Precise relative humidity accuracy: ±7.5 % RH, 30 – 70 % RH; ±15 % RH, 15 – 40 % RH, 70 – 90 % RH</li> <li> Highly accurate temperature measuring: ±1 °C (Max.), 10 – 40 °C; ±1.5 °C (Max.), –10 – 10 °C, 40 – 75 °C</li> <li> Supports up to 8 daisy-chained devices</li> <li> Multiple interfaces to broaden applications –<br /> – 1 x RJ-45 input port, 1 x RJ-45 output port, and 1x RJ-11input port support connection with PG<a href="https://www.aten.com/global/en/resources/feature-articles/3-reasons-why-you-need-pdus-in-your-data-center-now/?utm_medium=internal_link" target="_blank"> PDU</a> series and <a href="https://www.aten.com/global/en/products/power-distribution-&-racks/accessories/ea1140/?utm_medium=internal_link" target="_blank">EA1140</a> / <a href="https://www.aten.com/global/en/products/power-distribution-&-racks/accessories/ea1240/?utm_medium=internal_link" target="_blank">EA1240</a> / <a href="https://www.aten.com/global/en/products/power-distribution-&-racks/accessories/ea1340/?utm_medium=internal_link" target="_blank">EA1340</a> environmental sensors<br /> – 1 x terminal block supports <a href="https://www.aten.com/global/en/products/power-distribution-&-racks/accessories/ea1440/?utm_medium=internal_link" target="_blank">EA1440</a> / <a href="https://www.aten.com/global/en/products/power-distribution-&-racks/accessories/ea1441/?utm_medium=internal_link" target="_blank">EA1441</a> / <a href="https://www.aten.com/global/en/products/power-distribution-&-racks/accessories/ea1442/?utm_medium=internal_link" target="_blank">EA1442</a> door sensor and <a href="https://www.aten.com/global/en/products/power-distribution-&-racks/accessories/ea1540/?utm_medium=internal_link" target="_blank">EA1540</a> capacitive leakage sensor</li> <li> Meets flexible installation purposes –<br /> – Included 1.5 m RJ-45 cable for ideal location placement<br /> – Contains a magnet for sticking to metallic surfaces<br /> – Included rack mount kits enable quick installation inside racks</li> <li> Overload protection prevents overheating of the protected equipment</li> <li> LED illumination is visible through the transparent enclosure</li> <li> Prevents device malfunctions thanks to early detection in case of overheating / excessive humidity</li> <li> Suitable for applications that require precise measuring, such as server rooms,<a href="https://www.aten.com/global/en/resources/white-papers/?utm_medium=internal_link#a-56" target="_blank"> data center</a>s, hospitals, smartfactories, and green offices</li> </ul> <p> </p> <table border="1" class="spec_table"> <tbody> <tr> <td class="title" colspan="2"> Electrical</td> </tr> <tr> <td class="subtitle"> Environment Sensor Ports</td> <td class="value"> 1 Port Terminal Block for Door Sensor (EA1440/EA1441/EA1442)/ Capacitive Leakage Sensor (EA1540)<br /> 1 Port RJ-11 for Original Temperature Sensor (EA1140/EA1240/EA1340)</td> </tr> <tr> <td class="title" colspan="2"> Measurement</td> </tr> <tr> <td class="subtitle"> Range</td> <td class="value"> Temperature: –10 to +75 °C<br /> Humidity: 0 to 100%</td> </tr> <tr> <td class="subtitle"> Accuracy</td> <td class="value"> Temperature:<br /> ±1°C (max), 10 to 40 °C<br /> ±1.5°C (max), –10 to 10 °C, 40 to 75 °C<br /> <br /> Humidity:<br /> ±7.5% RH, 30–70% RH<br /> ±15% RH, 15–40% RH, 70–90% RH</td> </tr> <tr> <td class="title"> Power Consumption</td> <td class="value"> DC12V:0.273W:1</td> </tr> <tr> <td class="title" colspan="2"> Environmental</td> </tr> <tr> <td class="subtitle"> Humidity (Operating & Storage)</td> <td class="value"> 0 – 80% RH, Non-Condensing</td> </tr> <tr> <td class="subtitle"> Temperature (Operating / Storage)</td> <td class="value"> –10 to 75 °C / -20 – 70℃</td> </tr> <tr> <td class="title" colspan="2"> Physical Properties</td> </tr> <tr> <td class="subtitle"> Dimensions (L x W x H)</td> <td class="value"> 10.44 x 3.57 x 2.14 cm<br /> (4.11 x 1.41 x 0.84 in.)</td> </tr> <tr> <td class="subtitle"> Weight</td> <td class="value"> 0.05 kg ( 0.11 lb )</td> </tr> <tr> <td class="subtitle"> Cable Length</td> <td class="value"> 1.5M(RJ45+RJ45) round cable</td> </tr> <tr> <td class="subtitle"> Housing</td> <td class="value"> Black Polycarbonate</td> </tr> <tr> <td class="title" colspan="2"> Compliance</td> </tr> <tr> <td class="subtitle"> EMC Verification</td> <td class="value"> EMC/FCC, Class A</td> </tr> <tr> <td class="subtitle"> Safety Verification</td> <td class="value"> By Request</td> </tr> <tr> <td class="title" colspan="2"> LEDs</td> </tr> <tr> <td class="subtitle"> LED Indicator</td> <td class="value"> [Solid]: EA1640 is in working mode<br /> [Fast Blinking (for 2 minutes)]: EA1640 receives the command “FindMe”.<br /> [Slow Blinking (for 10 seconds)]: Over-current protection (OCP) is triggered, and the sensor(s) connected to EA1640 is going to power off.<br /> [Slow Blinking]: Firmware upgrade of EA1640 is in progress.</td> </tr> </tbody> </table> <p> </p> <div class="package-content"> <h3> Package Contents</h3> <ul> <li> 1 x Temperature & Humidity Sensor</li> <li> 2 x rack mount kits</li> <li> 1 x RJ45 Cable</li> <li> 1 x User Instructions</li> </ul> </div> <p> </p> </div> </div> <p> </p>